Drawing-Defined Cold Plates
Cold plates specified through customer-controlled drawings, fluid interfaces and defined acceptance conditions.
Explore rangeProduct group
Customer-defined thermal components considered through drawing, interface and acceptance requirements.

Narrow your selection

Cold plates specified through customer-controlled drawings, fluid interfaces and defined acceptance conditions.
Explore range
Component-level heat exchangers selected around a fully defined thermal duty.
Explore rangeComponent selection
5 local draft records. Includes unfinished records and Family overviews. Draft · Noindex. Reference configurations are not approved stock. Image public-use review remains separate.
Show content-ready drafts
LCP-000038
A pictured four-pass copper-tube-in-extruded-aluminum cold plate with two published unfinished standard lengths and order codes. Width and tube geometry are sourced; the…

LCP-000042
A separately pictured LGA3647 direct-contact microchannel cold plate with copper base and fins and published 108 × 78 × 19.1 mm nominal…

LCP-000040
A pictured direct-to-chip microchannel cold plate listed for LGA4677, with a copper base and fins and published 118 × 78 × 19.1…

LCP-000047
A separately pictured aluminum plate with a routed copper tube pressed into the substrate; the supplier lists AL6063 and epoxy bonding, with…

LCP-000041
A separate pictured SP5/LGA6096 cold plate listed for AMD EPYC 9004, with copper base and fins and published 118 × 78.9 ×…
Specify with confidence
Define the customer-owned design, interfaces and acceptance conditions before discussing a component quotation.
Thermal components require a specified duty, geometry and fluid boundary. Cold plates can be reviewed against buyer-controlled drawings; other thermal categories remain limited pending exact evidence.
State heat load, fluid conditions, mounting, interfaces and thermal and hydraulic acceptance methods. Do not infer performance from a different plate or test arrangement.
Include the drawing or specification revision and identify any requirements that are still to be confirmed. Available configurations, testing and documentation are confirmed with quotation.
Local editorial preview
Manufacturer examples retain their model and conditions. These references describe source products, not approved stock or supply. Images are pending final selection and rights review.










| Parameter | Documented value / configuration |
|---|---|
| Drawing configuration | tube-in-plate; aluminum vacuum-brazed; micro-channel |
| Parameter | Documented value / configuration |
|---|---|
| Fluid interface | Copper tube, 9.5 mm OD x 1.24 mm wall; termination details require drawing review. |
| Parameter | Documented value / configuration |
|---|---|
| Plate material and construction | Extruded aluminum plate with continuous copper tube press-fit and thermally conductive aluminum-filled epoxy at the jointConditions: scope: Published standard configuration; no site manufacturing capability claim |
| Copper tube geometry | 9.5 mm outside diameter, 1.24 mm wallConditions: scope: Datasheet standard copper tube; connection termination and fluid path test require selected drawing |
| Listed plate width | 127 mmConditions: scope: Standard family width, not thickness; thickness row has unresolved metric/imperial discrepancy and is excluded |
| Standard 152mm order code | 416501U00000G — unfinished, 152 mm plate lengthConditions: scope: Exact published standard part number; verify current revision before quote |
| Standard 305mm order code | 416601U00000G — unfinished, 305 mm plate lengthConditions: scope: Exact published standard part number; verify current revision before quote |
| Listed tube material options | Stainless steel or cupronickel tube listed as custom alternativesConditions: scope: Custom option; not a property of the pictured copper-tube standard code |
| Parameter | Documented value / configuration |
|---|---|
| Socket family | LGA 4677Conditions: scope: Manufacturer product page; physical mounting, hose ports and CPU-specific fit require drawing review |
| Listed plate length | 118 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed plate width | 78 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed plate height | 19.1 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed material construction | Copper base and copper fins; microchannel liquid-cooling constructionConditions: scope: Manufacturer description; no wetted-material certificate or measured thermal/hydraulic condition supplied |
| Pictured fluid interface | The manufacturer's product image shows two opposed metallic hose-barb-shaped fluid ports on raised blocks of the assembled plateConditions: scope: Visual interface type and arrangement only; no barb diameter, seal, hose compatibility or port pressure rating can be measured from the rendering |
| Parameter | Documented value / configuration |
|---|---|
| Socket family | SP5 / LGA6096, AMD EPYC 9004 seriesConditions: scope: Manufacturer-listed platform family; actual server mounting clearance and CPU fit require drawing review |
| Listed plate length | 118 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed plate width | 78.9 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed plate height | 25 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed material construction | Copper base and copper fins; microchannel liquid-cooling constructionConditions: scope: Manufacturer description; no wetted-material certificate or measured thermal/hydraulic condition supplied |
| Pictured fluid interface | The manufacturer's product image shows two opposed metallic hose-barb-shaped fluid ports on raised blocks of the assembled plateConditions: scope: Visual interface type and arrangement only; no barb diameter, seal, hose compatibility or port pressure rating can be measured from the rendering |
| Parameter | Documented value / configuration |
|---|---|
| Socket family | LGA 3647Conditions: scope: Manufacturer product page; physical mounting, hose ports and CPU-specific fit require drawing review |
| Listed plate length | 108 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed plate width | 78 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed plate height | 19.1 mmConditions: scope: Published nominal outer dimension, not a tolerance-controlled drawing |
| Listed material construction | Copper base and copper fins; microchannel liquid-cooling constructionConditions: scope: Manufacturer description; no wetted-material certificate or measured thermal/hydraulic condition supplied |
| Pictured fluid interface | The manufacturer's product image shows two metallic hose-barb-shaped fluid ports mounted on separate raised blocks of the plateConditions: scope: Visual interface type and arrangement only; no barb diameter, seal, hose compatibility or port pressure rating can be measured from the rendering |
| Parameter | Documented value / configuration |
|---|---|
| Plate construction | Copper tube pressed into a rectangular aluminum plate; epoxy bonding listed as additional processConditions: scope: Supplier-described construction; image shows tube path but does not establish bond quality or leakage rate |
| Listed plate material | AL6063 aluminum plate materialConditions: scope: Supplier page; tube grade, surface treatment and wetted-material certificate are not given |
| Dimension control | Plate dimensions customized to drawingConditions: scope: No standard outside size, tube OD, tube wall or mounting hole spacing published |
| Pictured fluid interface | The manufacturer's product image shows copper tube runs embedded in the plate and four visible tube-end stubs at one edge; the hydraulic pairing and end-fitting specification are not publishedConditions: scope: Visual routing and open end locations only; no tube OD, wall, end-connection standard, pressure or measured thermal performance inferred |
1 conflicting entries remain in the research review queue and are excluded from these specifications.