Product group
Sensing & Leak Detection
Flow, pressure, temperature and leak-detection components specified around measurement points and equipment interfaces.

Narrow your selection
Explore product families.


Flow, Pressure & Temperature Sensors
Flow, pressure and temperature sensors selected by measurement requirements, fluid connections and electrical interfaces.
Explore range
Leak Detection Components
Point or cable-based detection components for a stated coverage and alarm interface.
Explore rangeComponent selection
All Product drafts
Private preview · candidate records
12 local draft records. Includes unfinished records and Family overviews. Draft · Noindex. Reference configurations are not approved stock. Image public-use review remains separate.
Show content-ready drafts
LCP-000092
Braided Conductive Leak Detection Cable — MA1YHZ0102 Reference
A conductive, braided leak-sensing cable documented for liquid-cooling equipment. The manufacturer identifies the MA1YHZ0102(1.0) reference and an operating temperature range of -40…
- Operating temperature
- -40 to 70 °C
- Detection method
- Conductive-liquid detection through internal conductors

LCP-000094
Dual-Principle Spot Leak Sensor with RS485 — XW-DC-01A Reference
A compact spot sensor combining optical and electrode detection, with RS485/MODBUS-RTU output. The documented XW-DC-01A uses a DC 9–30 V supply and…
- Supply voltage
- DC 9–30 V; 12 V recommended
- Signal interface
- RS485; MODBUS-RTU

LCP-000104
Four-Channel Flow Monitor — SMC PFG200 Reference
A separate three-screen monitor for up to four compatible flow-sensor channels. The original product photo shows the display unit alone; fluid-contacting sensors…
- Accumulated flow
- Monitor can manage accumulated flow for up to four lines
- Product type
- Separate three-screen, four-channel flow monitor; sensing heads are separate products

LCP-000093
Helical Locating Leak-Sensing Cable — XW-ES2-10H1 Reference
A coiled, connector-terminated leak-sensing line for use with a compatible locating controller. The documented XW-ES2-10H1 cable is 6.0 mm in diameter and…
- Cable diameter
- 6.0 mm
- Operating temperature
- -20 to 75 °C

LCP-000012
Integrated Flow, Pressure and Temperature Sensor — FJP Series
An identifiable in-line FJP sensor with a single body for three measured variables; the manufacturer's size-specific flow rows, threads and output choices…
- Flow measurement principle
- Hall-sensed impeller
- Nominal diameter options
- DN6, DN8, DN10, DN15, DN20, DN25

LCP-000064
Integrated Water Flow Sensor — SMC PF3W720-04-A Reference
An official 800 × 532 product photograph clearly identifies PF3W720-04-A, with a built-in display and two threaded fluid ports. The corresponding maker's…
- Configuration and ports
- PF3W720 integrated-display flow sensor; 04 = Rc 1/2 ports; A = NPN/NPN switching outputs
- Rated flow range
- 2–16 L/min nominal rated flow range

LCP-000096
Locating Leak Detection Controller — XW-PC-3 Reference
A DIN-rail-style controller for a compatible locating sensing cable, with RS485 and relay outputs. The XW-PC-3 reference lists a monitored run up…
- Monitored cable length
- Up to 150 m with matching locating sensing cable
- Supply voltage
- DC 9–30 V; 12 V recommended

LCP-000034
MEMS Pressure Transmitter for Liquid Cooling — Danfoss DST P140 Reference
A separately pictured DST P140 pressure-transmitter series reference for liquid-cooling data centers, with MEMS and sealed stainless media-interface construction. Range, signal, connector…
- Gauge pressure range
- 0 to 10 bar
- Output signal
- 4 to 20 mA

LCP-000121
Modular Water-Sensing Cable with Factory Connectors — Raychem TT1000 Reference
A complete modular water-sensing cable with factory-installed plastic connectors. The Raychem TT1000 series is documented for data-center subfloors and pipe-adjacent leak detection…
- Cable diameter
- 6.0 mm nominal
- Available modular lengths
- 1, 3, 5, 7, 15, 30 and 50 m catalog versions with factory-installed connectors

LCP-000005
Multi-Circuit Liquid Leak Detection Controller
A separately housed leak-detection panel that monitors sensing-cable circuits and provides alarm outputs; the pictured device is an exact model reference, not…
- Output
- eight programmable alarm relays; power-fail relay; Modbus over RS232/RS422/RS485
- Coverage
- location accuracy m: 1; maximum per circuit m: 600; maximum total m: 1800

LCP-000095
Optical Spot Leak Sensor with Relay Output — XW-DC-01B Reference
A stand-alone optical point leak sensor with one configurable dry-contact output. The documented XW-DC-01B uses DC 9–30 V and a normally open…
- Supply voltage
- DC 9–30 V; 12 V recommended
- Signal interface
- One dry-contact relay; normally open or normally closed

LCP-000103
Remote Water-Flow Sensor — SMC PF3W504-03-1-Z Reference
An inline remote flow-sensing unit with its own cable connection but no integrated numeric display. The original unit label identifies 0.5–4 L/min,…
- Rated flow range
- 0.5–4 L/min marked on the pictured unit; not a range for all PF3W5 models
- Analog output
- 1–5 V marked on the pictured unit
Specify with confidence
The details that shape your selection.
Identify the measured variable or detection task, process connection, output interface and verification requirements.
- Function and loop position
- Interfaces, drawing revisions and envelope
- Coolant, materials and seals
- Temperature, pressure and flow conditions
- Testing and documentation
- Quantities and delivery requirements
System and selection context
Measurement and leak detection help define the monitored boundary of a liquid loop. Pumps remain outside the current active sourcing focus.
Inputs for review
Specify each measurement or detection point, process connection, electrical interface, operating range and buyer-owned alarm or controls integration.
Information to prepare
- Identify the measured variable or detection task, process connection, output interface and verification requirements.
Configuration and quotation
Include the drawing or specification revision and identify any requirements that are still to be confirmed. Available configurations, testing and documentation are confirmed with quotation.
Documented reference configurations & supporting imagery
Local editorial preview
Related component references
Manufacturer examples retain their model and conditions. These references describe source products, not approved stock or supply. Images are pending final selection and rights review.
Flow, Pressure & Temperature Sensors
63 documented parameter entries. Open the family to review model scope, options and conditions.
Leak Detection Components
43 documented parameter entries. Open the family to review model scope, options and conditions.