Technical selection
Specifications and configuration
Reference — VNB Series
| Parameter | Documented value / configuration |
|---|---|
| Product type | Two-port process valve with air-operated or external-pilot solenoid forms |
| Applicable media | Air, water, oil, gas or vacuum according to body and seal selection |
| Orifice options | 7–50 mm across listed configurations |
| Port options | Rc (PT) 1/8 to 2 across listed configurations |
| Seal options | NBR, FKM or EPR listed by configuration |
Reference — VNB Series, selected actuation code
| Parameter | Documented value / configuration |
|---|---|
| Code dependent operating pressure | The VNB instruction table distinguishes low vacuum to 0.5 MPa and low vacuum to 1 MPa operating-pressure configurations; it does not assign one maximum to every VNB valveConditions: scope: Reference only until full VNB ordering code, actuation, seal, medium and pressure differential are confirmed; this is not a site supply rating |
Reference — VNB Series, selected actuation and seal code
| Parameter | Documented value / configuration |
|---|---|
| Code dependent fluid temperature | The instruction table lists -5 to 60 °C for its listed solenoid/standard configurations and -5 to 99 °C for specified air-operated water/oil configurations, both without freezingConditions: scope: The 99 °C row is restricted to air-operated water/oil configurations; do not apply it to every VNB or every coolant |
Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.
Overview
The VNB is an actuated two-port valve option where a buyer needs remotely operated fluid shutoff or routing in a secondary liquid loop. It is not the direct-acting JSX solenoid valve already listed in this catalog.
Construction and interfaces
The official series photograph shows two VNB valves with different body sizes and pilot assemblies. The maker lists air-operated and external-pilot solenoid forms, with NBR, FKM or EPR seal choices.
Selection
Select the exact body, pilot actuation, normally-open/closed behavior and seal for the coolant. SMC lists water among possible fluids only when materials and configuration are chosen appropriately.
Configuration options
The catalog span of 7–50 mm orifice and Rc (PT) 1/8 to 2 ports represents different order configurations, not one valve's range of motion or a stock promise.
Application limits
SMC's instruction table separates low-vacuum-to-0.5 and low-vacuum-to-1 MPa pressure configurations; fluid temperature is -5 to 60 °C for listed standard/solenoid configurations and may reach -5 to 99 °C only for specified air-operated water/oil configurations, without freezing. None is a universal VNB rating: confirm the order code, seal, pilot duty and coolant. The pair photograph is a series reference.