Private previewCandidate · Draft · Noindex. Reference configuration; supply and public media use require confirmation.

LCP-000016 / Product configuration

Floating Blind-Mate Coupling — CGB Series Reference

A distinct CGB floating blind-mate socket-and-plug reference with external fastening, documented alignment claim and model-separated water-flow rows; not interchangeable by name with other blind-mate series.

Size specific recommended flow
CGB03 2.1; CGB05 5.9; CGB08 15.1; CGB12 33.9 L/min
Listed material choices
Aluminum-alloy and stainless-steel part-code columns
Size specific socket plug end examples
For CGB03, the order tables separately list G1/8 male-thread socket CGB03.1342-G18 and plug CGB03.7342-G18 in stainless-code columns; alternate ends and body materials have other codes
Listed seal options
CGB series summary lists EPDM and FVMQ sealing-ring options; the selected order code and coolant compatibility must be verified.
Series pressure temperature reference
CGB series summary lists working pressure 0–100 psi and working temperature -55 to +120 °C; the selected pair, seal and coolant require configuration review.

Technical selection

Specifications and configuration

Reference — CGB series

ParameterDocumented value / configuration
RetentionNo integral lock; externally fastenedConditions: scope: blind-mate structure requires equipment-level retention
Claimed alignment compensationplus or minus 1.5 mmConditions: scope: manufacturer series claim; validate exact size, mounted stack and stroke
Size specific recommended flowCGB03 2.1; CGB05 5.9; CGB08 15.1; CGB12 33.9 L/minConditions: scope: separate model rows, water 20 degC, plug-to-socket, 5 m/s velocity criterion; CGB10 appears in ordering table but not this flow row
Listed material choicesAluminum-alloy and stainless-steel part-code columnsConditions: scope: material depends on exact code; seal and all wetted material need verification
Size specific socket plug end examplesFor CGB03, the order tables separately list G1/8 male-thread socket CGB03.1342-G18 and plug CGB03.7342-G18 in stainless-code columns; alternate ends and body materials have other codesConditions: scope: Example series pair; verify mounted geometry, material, seal and selected mating halves
Listed seal optionsCGB series summary lists EPDM and FVMQ sealing-ring options; the selected order code and coolant compatibility must be verified.Conditions: scope: Manufacturer series options, not proof of the pictured part's installed seal
Series pressure temperature referenceCGB series summary lists working pressure 0–100 psi and working temperature -55 to +120 °C; the selected pair, seal and coolant require configuration review.Conditions: scope: Manufacturer series summary; not a combined end-code and coolant approval

Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.

Overview

This CGB-style floating blind-mate connection provides a guided mating interface for equipment where the insertion movement is imposed by the rack or module. The rendering shows the distinct two-part series form.

Construction and interfaces

The manufacturer identifies no integral lock, so a surrounding structural fastener retains the connected halves. The source includes separate aluminum-alloy and stainless-steel part-code columns; material follows the chosen code.

Selection

Review the manufacturer-stated alignment allowance together with mounted datums, insertion travel and off-axis loads. CGB03, 05, 08 and 12 have distinct recommended water-flow rows, while another listed order size is not in that flow table.

Configuration options

Choose the exact model row, socket and plug, body material column, each end connection, mounting and seal configuration. The illustration represents series appearance, not a dimensioned drawing for every CGB variant.

Application limits

The maker lists EPDM/FVMQ seal options and a 0–100 psi, -55 to +120 °C series summary; the chosen order code, coolant and installed pair still require joint review. Do not equate this CGB alignment claim or flow value with MQDB, UQDB or Xinda CYFBI parts. Installed correction capability and leakage need the exact pair and test method.