Private previewCandidate · Draft · Noindex. Reference configuration; supply and public media use require confirmation.

LCP-000055 / Product configuration

Automatic Water Flow Controller — SMC FC2W520-04-3-X110 Reference

An inline powered flow controller for water circuits, with a 2–16 L/min control range, Rc 1/2 ports and 24 VDC input. The pictured controller is a manufacturer-series reference.

Rated flow control range
2.0–16.0 L/min
Process port
Rc 1/2
Working pressure
0.2–0.4 MPa at 0–50 °C fluid temperature; proof pressure 0.6 MPa
Listed medium and temperature
Water; fluid temperature 0–50 °C without freezing
Ordering code
FC2W520-04-3-X110; 1/2 in. Rc port; 3 m lead

Technical selection

Specifications and configuration

Reference — SMC FC2W520-04-3-X110

ParameterDocumented value / configuration
Ordering codeFC2W520-04-3-X110; 1/2 in. Rc port; 3 m leadConditions: scope: Exact catalogue ordering example
Rated flow control range2.0–16.0 L/minConditions: medium: Water; catalogue specified operating conditions
Process portRc 1/2Conditions: scope: Confirm mating thread and line size in RFQ
Working pressure0.2–0.4 MPa at 0–50 °C fluid temperature; proof pressure 0.6 MPaConditions: scope: Proof pressure is not the normal working range
Control accuracy±5% F.S. flow-control accuracy; response time ≤10 sConditions: scope: Catalogue condition; not a fast-acting safety shutoff
Power and signal24 VDC ±10%; 0–5 VDC analogue flow-command input; flow-pulse outputConditions: scope: Check controls integration and wiring diagram
Listed medium and temperatureWater; fluid temperature 0–50 °C without freezingConditions: scope: Do not infer glycol or other coolant compatibility from water rating
Shutoff limitationController cannot fully close; an external shutoff valve is needed for emergency stopConditions: scope: Functional boundary of FC2W-X110 series

Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.

Overview

SMC FC2W-X110 automatically adjusts water flow within a preset range. The PDF photograph shows the FC2W520 body and controller; the exact wiring/port suffix is defined by its catalogue ordering code.

Construction and interfaces

The illustrated unit combines two inline threaded ports, an electrically powered controller and a local status interface. The pictured series body is complete and suitable as a local reference main image.

Selection

The FC2W520-04-3-X110 example uses Rc 1/2 ports and controls 2–16 L/min of water at 0–50 °C. Published normal pressure is 0.2–0.4 MPa; 0.6 MPa is a separate proof value.

Configuration options

The same family includes a smaller FC2W504 range. Confirm the exact model code, port size, 3 m lead, 24 VDC supply, analogue command and pulse-output interface before specifying controls.

Application limits

The catalogue says the controller does not fully close, so use a separate shutoff valve for emergency stop. Do not assume glycol or other coolant compatibility from this water-only entry.